Enzyme-Linked Immunosorbent Assay (ELISA)




What is an ELISA?

ELISA, or enzyme-linked immunosorbent assay, is a method used to quantitatively detect an antigen within a sample. An antigen is a toxin or other foreign substance, for example a flu virus or environmental contaminant, that causes the vertebrate immune system to mount a defensive response. The range of potential antigens is vast, so ELISAs are used in many areas of research and testing to detect and quantify antigens in a wide variety of sample types. Cell lysates, blood samples, food items, and more can be analyzed for specific substances of interest using ELISAs.

Steps to run a sandwich ELISA assay

Most ELISAs are run in microplates, with the bottom of the microplate wells serving as the solid surface to which antibodies and other reagents bind. A microplate washer is used to wash away non-specific material in the wells, and a microplate reader detects the color change produced when target antigen is present. An ELISA’s plate reader software is used to plot standard curves and calculate results.

Here are the steps used for a typical sandwich ELISA assay:

ELISA analysis and techniques

ELISA is a commonly used analytical technique performed in many research and biotech labs. Below is a collection of application notes, research and technology related to significant ELISA assays and applications. We’ve started with a brief introduction of the four common types of ELISAs including direct, indirect, competitive, and sandwich.


  • Direct ELISA

    The antigen is bound to the bottom of the microplate well, and then it is bound by an antibody that is specific to the antigen and also conjugated to an enzyme or other molecule that enables detection.

    Indirect ELISA

    The antigen is bound to the bottom of the microplate well, then an antibody specific to the antigen is added. A secondary antibody, conjugated to an enzyme or other detection molecule, is then bound to the first antibody.

  • Competitive ELISA

    In this type of ELISA, a reference antigen is bound to the bottom of microplate wells. Sample plus antibody are added to the wells, and if there is antigen present in the sample, it competes with reference antigen for binding to the antibody. Unbound material is washed away. The more antigen was in the sample, the less antibody ends up bound to the bottom of the wells by the reference antigen, and the lower the signal.

    Sandwich ELISA

    For this type of ELISA, two antibodies specific to two different epitopes on the target antigen are used. The capture antibody is bound to the bottom of the microplate well and binds one epitope of the antigen. The detection antibody binds to the antigen at a different epitope and is conjugated to an enzyme that enables detection. (If the detection antibody is unconjugated, then a secondary enzyme-conjugated detection antibody is required).

  • Faster ELISA Results

    使用 CatchPoint SimpleStep ELISA 试剂盒可以更快地获得 ELISA 结果

    A typical ELISA protocol is time-consuming, with multiple incubation and wash steps. CatchPoint SimpleStep ELISA 试剂盒为用户提供了一个 90 分钟的 ELISA 工作流程,与传统 ELISA 相比,时间缩短了大约三分之二。

    阅读应用说明  

    Quantitate Interleukin-8 ELISA

    Quantitate interleukin-8 concentrations in just 90 minutes

    了解如何在 SpectraMax® ABS Plus 微孔读板机(酶标仪)上使用便利的预配置方案进行人 IL-8 SimpleStep ELISA。

    阅读应用说明  

  • Melamine Detection with ELISA Kit

    使用 Abraxis Melamine ELISA Kit 和 Molecular Devices 光吸收酶标仪(读板机)进行高通量三聚氰胺检测

    The Abraxis Melamine enzyme-linked immuno-sorbent assay (ELISA) is an immunoassay for quantitative screening of melamine; based on the recognition of melamine by antibodies.

    阅读应用说明  

    ELISA – Cytokine Interleukin-22

    使用 EMax Plus 微孔读板机(酶标仪)进行蛋白定量

    A performance comparison is made between the EMax Plus Microplate Reader and the EMax Endpoint Reader using a sandwich ELISA to quantitate levels of the cytokine Interleukin-22 (mouse/rat IL-22).

    阅读应用说明  

  • Chemiluminescent VEGF ELISA

    使用 SpectraMax L 微孔板发光光度计进行化学发光 VEGF ELISA检测

    Vascular endothelial growth factors (VEGFs) are a family of secreted polypeptides that have been implicated in mammalian vascular development and in disease processes involving abnormal blood vessel growth.

    阅读应用说明  

General ELISA protocol

A typical ELISA protocol has multiple reagent addition, incubation and wash steps. The ELISA workflow shows how a typical sandwich ELISA is run. Each step breaks down the ELISA process and highlights the instrumentation and tools needed to conduct the ELISA assay including a microplate washer, absorbance reader and plate reader software.

 

ELISA Assay Protocol Workflow
 

CAPTURE ANTIBODY BINDS TO WELLS

First, the capture antibody is bound to the bottom of the microplate well.

ELISA 板

Most ELISAs are run in 96- or 384- well microplates, a 96-well plate being the most common. The bottom of the microplate wells serve as the solid surface to which antibodies and other reagents attach. Microplates are typically included in an ELISA kit.

01

Want faster ELISA results?

CatchPoint SimpleStep ELISA kits produce results in just 90-minutes!

了解更多信息 

ADD SAMPLE

Sample is added to the well, and antigen within the sample binds to the capture antibody.

02

WASH MICROPLATE

Unbound material is washed away, leaving only the antigen of interest and minimizing the potential for high background signal.

elisa 洗板机

A microplate washer is used to wash away non-specific material in the wells.

View product video 
03

ADD DETECTION ANTIBODY

Enzyme-conjugated detection antibody binds to a second site on the antigen of interest, providing the means to detect the antigen.

04

WASH MICROPLATE

Unbound antibodies are washed away, leaving only those specific for the target of interest and again minimizing the potential for background signal.

AquaMax 微孔洗板机

在所有孔中同时进行 96 和 384 孔抽吸和分配,可实现高精度检测和更快的微孔板处理,无需进行机械板索引或象限处理。

View product video 
05

ADD SUBSTRATE

Substrate is converted by the enzyme on the detection antibody, producing a color change, with intensity proportional to the amount of antigen present.

Depending on the enzyme and substrate used, the readout can also be fluorescent or luminescent.

06

READ PLATE

The microplate reader detects the colored reaction product and outputs optical density (OD) values that indicate how much light is absorbed by the contents of each well.

ELISA 酶标仪(读板机)

A microplate reader detects the color change produced when target antigen is present. It does so by measuring how much of the light passed through the wells of the microplate is absorbed by the material within the wells. The more antigen is present, the higher the absorbance value.

View product video 
07

ELISA Plate Reader Software

Software is used to plot standard curves and calculate results from the absorbance values provided by the microplate reader.

A standard curve is run so that the amount of antigen in each sample can be accurately calculated. A preconfigured protocol, helps save time by calculating results automatically.

View product video 

CALCULATE RESULTS

The amount of antigen in each sample is calculated, and different samples—for example, cells subjected to different treatment conditions—can be compared.

08

 

Resources for ELISA

相关产品和服务

准备好了吗?

我们已准备好帮助您解决在研究中遇到的严峻挑战。我们具有遍布全球的经验丰富的专业技术团队,可帮助您实现下一个突破。